Openreach deploys Ciena optics for UK data centres
·

Openreach deploys Ciena optics for UK data centres

Openreach is deploying Ciena optical transport equipment to extend high-capacity UK wholesale connections serving data centres and cable landing stations. The announcement specifies 1.6Tb/s wavelengths and 400G and 800G client…

Openreach deploys Ciena optics for UK data centres
Summary
  • Openreach is deploying Ciena Waveserver and WaveLogic 6 equipment within its UK Optical Spectrum Extended Access portfolio.
  • The announced solution includes 3.2Tb of scalable capacity, 1.6Tb/s wavelengths, and 400G and 800G customer interfaces.
  • Ciena will support deployment, monitoring and maintenance, while route-by-route availability and commissioning details remain undisclosed.

Openreach is deploying Ciena Waveserver optical transport equipment in its UK wholesale network, adding WaveLogic 6 technology capable of carrying 1.6Tb/s on an optical wavelength. Announced on 7 October, the upgrade is intended to support 400G and 800G customer services and higher-capacity connections serving data centres, cable landing stations and core network locations.

The companies describe 3.2Tb of scalable capacity over diverse fibre routes as part of the deployment into Openreach’s Optical Spectrum Extended Access (OSEA) portfolio. That figure describes the announced solution rather than the capacity of every existing fibre route. Openreach has not disclosed how many routes have been equipped, which customer circuits have been commissioned or when deployment will be complete.

Connecting data centres and landing stations

Openreach uses OSEA to provide optical connectivity for wholesale customers with requirements that extend beyond standard access services. Ciena says the enhanced portfolio can serve specialist locations including submarine cable landing stations, access and backhaul connections to core network nodes, and data centres. These are defined applications for the technology, not a list of newly activated customer contracts.

Large data centres depend on external transport networks to exchange traffic with cloud regions, internet providers, other facilities and international systems. Optical links between those locations may carry different types of traffic from the networks inside a computing campus. An 800G interconnection service concerns the capacity of the customer-facing transport connection; it does not specify the switching capacity of a data centre or the throughput available to every application it hosts.

Submarine cable landing stations create another requirement for terrestrial transport. Traffic arriving on an international cable must be carried onward to inland networks and computing facilities, sometimes across multiple operators’ systems. More capable wavelengths may increase what an existing fibre route can transport, provided the route and its equipment support the configuration.

The announcement also highlights diverse fibre routing. Separating paths can support continuity where customers purchase and provision appropriate protection, but the release does not identify specific geographically diverse routes or state how resilience has changed for any live customer. Physical route separation and the configuration of the connected services remain necessary to establish the operational benefit.

What the optical specifications mean

Ciena’s Waveserver uses coherent optical transmission, combining optical components with digital signal processing to encode high volumes of data onto fibre. WaveLogic 6 supports 1.6Tb/s transmission on a wavelength in the stated deployment, with 400G and 800G client traffic carried over dedicated optical channels. The rate achieved on any particular span depends on its optical conditions and the deployed configuration.

The release specifies a two-rack-unit chassis supporting up to 32 400G services. This is a chassis interface or aggregation specification, and should not be added to the 3.2Tb scalable capacity figure as though they describe the same measure. Likewise, 1.6Tb/s is the stated wavelength capability, while 400G and 800G are the customer service interface rates identified for the offering.

Equipment density affects the space, power and management requirements of optical transport installations, although the companies have not disclosed measured power consumption or cost savings for this particular deployment. Nor do they identify the number of chassis installed in Openreach sites. Those omissions prevent a quantified assessment of energy efficiency, equipment footprint or aggregate commissioned network capacity.

Openreach describes the upgrade as introducing national 800G services to its wholesale portfolio. The announcement demonstrates an intended new service capability and an active equipment deployment, but does not establish that an 800G circuit is available at every Openreach location. Route engineering, equipment installation, testing and individual service activation determine when a customer can use it.

Operations and rollout

Ciena will provide managed services associated with deployment, proactive monitoring and maintenance of the OSEA optical product. These services extend the supplier’s involvement beyond delivering hardware. Monitoring can expose equipment and signal conditions to operational teams, but the announcement contains no measured reduction in faults, outage duration or maintenance costs attributable to the new installation.

The upgrade builds on an existing supplier relationship. Openreach had previously adopted Ciena technology in its optical networking portfolio, while the new announcement specifically concerns Waveserver and WaveLogic 6 capacity in OSEA. It is therefore an expansion of a wholesale transport offering rather than the construction of a new data centre or a replacement for the entire UK fibre network.

The companies have not provided an investment value, route-by-route timetable, customer take-up figures or a final commissioning milestone. The deployment establishes a path to larger optical services linking the UK’s digital infrastructure locations; the extent of operational availability will become measurable as routes and individual customer connections are activated.