Summary
- Two existing Nordic customers have ordered a combined 430 customised Avalon A1566HA-500T computing units.
- The equipment is designed to deliver hot water at approximately 80°C for integration with district heating networks.
- Canaan estimates that its combined Nordic projects could provide heat equivalent to the requirements of nearly 8,000 homes.
Canaan has secured two additional equipment orders for Nordic district heating developments, expanding its regional deployment of liquid-cooled computing infrastructure designed to produce recoverable thermal energy alongside cryptocurrency mining.
The orders, disclosed on 25 November, cover 430 customised Avalon A1566HA-500T units for two separate district heating locations. Each unit has a rated computational performance of 500 terahashes per second, giving the equipment a combined cryptocurrency mining capacity of approximately 215 petahashes per second.
Canaan has designed the equipment to provide hot water at approximately 80°C, allowing thermal energy generated by the computing hardware to be transferred into local district heating infrastructure.
The developments build on an 8MW Nordic district heating project announced in May. Canaan estimates that its combined regional project portfolio now approaches 12MW of capacity, potentially providing heat equivalent to the requirements of nearly 8,000 homes.
Both orders resulted from competitive supplier selection processes involving existing customers. One followed more than four months of technical and commercial discussions, while the other came from a customer that had previously purchased equipment through Canaan’s Nordic heating initiatives.
The customers have not been identified, and Canaan has not disclosed the value of the orders, their individual thermal capacities, or the commercial terms under which the district heating networks will purchase recovered energy.
Recovering heat at useful temperatures
Liquid cooling allows thermal energy generated by computing equipment to be captured within a circulating fluid rather than being dispersed directly into surrounding air. The recovered heat can subsequently be transferred into another circuit through a heat exchanger.
The operating temperature of that fluid has a substantial influence on the practicality of heat recovery. Water leaving conventional computing infrastructure may be considerably cooler than the temperatures required by established district heating networks, particularly those designed to serve older buildings during winter.
Increasing the temperature of recovered heat normally requires additional equipment and electricity. Heat pumps can provide that temperature increase, but their efficiency depends partly on the difference between the incoming heat source and the required delivery temperature.
Canaan’s intended water output of approximately 80°C could reduce the additional temperature increase required for some district heating applications. Whether the equipment can supply heat directly through a heat exchanger will depend on network temperature requirements, operating conditions, and the design of the installation.
The equipment’s thermal output must also remain compatible with the operating characteristics of the computing hardware. Canaan has previously described using adjustments to processor operating parameters to control heat production within its Nordic installations.
Cryptocurrency mining provides greater scope for such adjustments than some conventional data centre workloads because individual computing units can generally operate independently. Reducing their processing activity affects mining revenue, but does not necessarily interrupt customer applications or other hosted business services.
Operators considering similar arrangements for enterprise computing or AI infrastructure must account for service availability requirements, hardware temperature limits, and customer contracts, which may restrict their ability to change electricity consumption in response to external heating demand.
Commercial integration with district heating
District heating operators must maintain reliable supplies even when computing equipment is unavailable. Conversely, computing facilities need sufficient cooling when external heat demand is low or the heating network cannot accept their thermal output.
Seasonal variation can make that relationship difficult to manage. Residential heating demand generally increases in winter, while computing infrastructure may continue generating substantial heat during warmer months. Alternative heat rejection equipment or flexible computing operations may therefore remain necessary.
The commercial arrangements must address those operating conditions alongside the ownership, maintenance, and financing of heat recovery equipment. The value of the recovered energy will depend on the amount delivered and the cost of the alternative heat production it replaces.
Canaan expects its latest installations to displace some heat that would otherwise be produced through fuel combustion. Assessing their environmental performance will require information about the displaced fuel, the electricity supplied to the computing hardware, and any additional energy used for pumping or temperature adjustment.
The estimated heating potential for nearly 8,000 homes describes the company’s wider regional portfolio rather than a confirmed number of connected households. Annual heat deliveries will depend on the projects’ operating hours, recovery efficiency, and seasonal demand.
The two new orders extend Canaan’s existing commercial relationships in Nordic district heating. Their subsequent deployment will provide further evidence of the operating temperatures, infrastructure availability, and commercial performance achievable when computing systems are designed around both processing activity and useful heat production.